Product Series |
Rack Mount 1~6kVA |
|
Model |
C1KR |
C2KR |
C3KR |
C6KR |
|
Rated Power |
VA/W |
1kVA / 0.7kW |
2kVA / 1.4kW |
3kVA / 2.1kW |
6kVA/4.2kW |
|
Input |
Nominal Voltage |
220VAC |
|
VoltageRange |
115 ~ 300VAC |
176 ~ 276VAC |
|
FrequencyRange |
46 ~ 54Hz(default), user adjustable within 40~60Hz |
46 ~ 54Hz |
|
Power Factor |
0.97 |
0.98 |
|
Connection |
IEC320-10A inlet |
IEC320-16A inlet |
Terminal Block |
|
Output |
Voltage |
220VAC±2% |
220VAC±1% |
|
Frequency |
46~54Hz or 50Hz±0.2Hz (Line mode) 50Hz±0.2Hz (Batterymode) |
46~54Hz (Line mode) 50Hz±0.05Hz (Batterymode) |
|
Waveform |
Sine Wave |
|
Overload Capability |
108%~150% for 30 sec.,³150% for 300 ms |
105%~130% for 10 min.,³130% for 1 min. |
|
Current Crest Ratio |
3:1 |
|
Bypass |
Automatic Transfer |
on overload and UPS failure |
|
Before UPS Power-on |
Default “NO”, user adjustable to “YES” |
Yes |
|
VoltageRange |
80~264VAC (Default), user adjustable within 80~286VAC |
176 ~ 261VAC |
|
Output Connections |
IEC320 -10A * 4 |
IEC320-10A * 4 |
IEC320-10A and Terminal Block |
IEC320-10A * 4 and Terminal Block |
|
Transfer Time |
0 ms; less than 4 ms from inverter to bypass and vice versa |
Zero |
|
LED indicators |
Status |
Load level /Batterylevel,Battery, Utility Power, Inverter, Bypass, Overload, Fault |
|
Audible Alarm |
Bypass, On battery mode,Batterylow, Overload, Fault |
|
Communications |
RS-232 Serial Interface |
|
|
|
Network Surge Protection |
RJ45 I/O port available for network or Fax/Modem |
|
Environmental |
Operating Temperature |
0 ~ 40°C |
|
Operating Humidity |
20 ~ 90% non-condensing |
|
Main Unit |
Net Weight (Kg) |
15.3 |